Rheem Water heater 16 Error Code
What the 16 code means
Outlet water temperature is above the set point. The outlet thermistor reports water hotter than the temperature set on the controller, so the control flags an outlet temperature fault — check the outlet thermistor first.
Likely causes
- Outlet thermistor scaled or failing, misreporting temperature
- Water bypass valve / bypass motor fault letting untempered water through
- Control board fault
How to fix it — step by step
- Access for the board-level checks below: switch the power OFF at the unit and remove the front cover (a screw at each corner) - the control board and its connectors are behind it. Close the gas and water shut-off valves before disconnecting any gas or water part, and let internal parts cool before handling them
- Check the outlet thermistor first: power OFF, remove connector C, and measure between the #3 (red) and #4 (black) wires — 7K–23K ohms is normal (full code 33 procedure).
- Clean scale from the outlet thermistor or replace the outlet thermistor if it reads out of range. → Shop the outlet thermistor at Amazon
- If the outlet thermistor tests good, test the water bypass valve using the code 66 bypass motor procedure; replace the bypass motor / water bypass valve if it does not operate. → Shop the water bypass motor at Amazon
- If both test good and code 16 persists, replace the control board. → Shop the control board at Amazon
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 16 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the outlet thermistor.
Shop the outlet thermistor at Amazon
Also tied to this fault: water bypass motor - Shop at Amazon; control board - Shop at Amazon
Parts that commonly fix the 16 code
- outlet thermistor$25–$80Shop at Amazon
- water bypass motorShop at Amazon
- control board$100–$300Shop at Amazon
- Tools for this job, if you need them$10–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.