Rheem Water heater 10 flashes

What it should look like on your machine

then it repeats

10 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Chamber temperature shutdown. The status light blinks red ten times every three seconds: combustion chamber temperature exceeded its safe limit and the control shut the heater down.

Likely causes

  1. Overheating inside the combustion chamber (blocked combustion air, flammable vapors, or burner fault)
  2. Failed chamber temperature sensing in the control

How to fix it — step by step

  1. Leave the heater off — a chamber over-temperature shutdown means something overheated where the burner fires; do not relight it until it is inspected.
  2. Locate the parts: the burner and combustion chamber are at the base of the tank, behind the outer door and the manifold (burner) door at the bottom front of the heater; the chamber temperature sensing is in the gas control mounted on the front of the tank (on this design the sensing is integral to the control, which is why the parts list names the gas control valve (thermostat)). Access for inspection is the outer door and manifold door — the technician works through those, not by opening the tank.
  3. The technician inspects the burner and combustion air openings for blockage, lint or flammable-vapor damage and checks the chamber sensor/control sensing: a found blockage or fouled burner corrected and proven by a normal firing cycle means the sensing was doing its job; a clean chamber with correct air supply and a repeat trip means the sensing/control has failed.
  4. Correct the overheating cause first, then replace the failed sensing/control parts (gas control valve (thermostat) where integral) — for a control swap: Replace the gas control valve/thermostat (A.O. Smith gas manual procedure, same threaded combination-control design): knob to OFF, gas off at the manual shut-off, drain the heater, disconnect the igniter wire and the red (+) and white (-) thermopile wires with needle-nose pliers, disconnect the pilot tube (7/16 in. wrench) and manifold tube (3/4 in. wrench; LP uses left-hand threads) at the control, disconnect the ground joint union and remaining gas pipe, then thread a 4 in. section of gas pipe into the inlet and use it — never a pipe wrench on the body — to turn the control counterclockwise out of the tank. Fit the new control in reverse with approved Teflon tape/pipe compound on the fitting that screws into the tank, do not overtighten, and remove the pilot ferrule nut from the new control. → Shop the gas control valve (thermostat) at Amazon
  5. Turn the main gas on and leak-test every gas connection with approved noncorrosive leak-detection solution (bubbles mean a leak — correct it), refill the tank completely before lighting, light the pilot and main burner per the label, and leak-test the manifold and pilot connections again with the burner lit.
  6. Tell the technician: 10 flashes chamber temperature shutdown, what was found in the chamber and air openings, and whether it re-trips after cleaning. What this job involves: burner/combustion inspection and possible gas-control replacement with gas leak testing — licensed gas work in most jurisdictions.
  7. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017
  • gas control valve (thermostat)$115–$500Shop at Amazon
  • combustion chamber sensorShop at Amazon
  • Tools for this job, if you need them$5–$25

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rheem Water heater problems