Rheem Water heater 71 Error Code
What the 71 code means
Solenoid valve (SV) circuit failure. The gas solenoid valve is not working properly and the control cannot prove the SV circuit, so it displays 71 and keeps the unit shut down.
Likely causes
- Loose or damaged solenoid valve wiring, or a poor connector 'D' connection
- Failed gas valve / manifold assembly
- Failed control board SV drive circuit
How to fix it — step by step
- Access for the board-level checks below: switch the power OFF at the unit and remove the front cover (a screw at each corner) - the control board and its connectors are behind it. Close the gas and water shut-off valves before disconnecting any gas or water part, and let internal parts cool before handling them
- Turn power OFF. Remove and reinsert connector 'D' and the molex connected to the built-in display, and visually inspect the wiring connected to the solenoid valves for loose or damaged connections. Turn power ON and operate the unit — if 71 clears, it was a loose connection.
- If 71 returns, test DC voltage between the #1 wire (yellow) and the #4 wire (black) at connector 'D': specification is 11-17 DC volts.
- If the voltage is out of range, recheck connector 'D' and operate the unit again; if 71 still appears, replace the control board. → Shop the control board at Amazon
- If the voltage is in range and 71 still appears on the next operation, replace the manifold assembly and gas valve. Gas valve work is qualified-technician work. → Shop the gas valve at Amazon
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 71 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the gas valve.
Also tied to this fault: control board - Shop at Amazon
Parts that commonly fix the 71 code
- gas valve$115–$500Shop at Amazon
- control board$100–$300Shop at Amazon
- Tools for this job, if you need them$10–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.