What this problem usually means
The gas tank heater makes hot water but runs out too fast or never gets hot enough. The bulletin's cause list runs from a low thermostat setting through a clogged burner orifice, low gas pressure, and a failed dip tube that mixes incoming cold water straight into the hot outlet.
Likely causes
- Thermostat set too low
- Defective dip tube mixing cold inlet water into the hot outlet
- Burner orifice clogged, under-firing the burner
- Clogged flueway restricting draft and firing
- Low gas supply / manifold pressure
- Venting downdraft or other improper draft
- Defective thermostat (gas control) — confirmed by a partial draw test
- Heater undersized for the household's peak demand
How to fix it — step by step
- Raise the thermostat setting on the gas control in a small step (keep the setting at a safe, non-scalding level) and allow a full recovery cycle, then retest.
- Inspect and clean the burner orifice so the burner fires at full rate.
- Inspect and clean the flueway through the center of the tank; a soot- or debris-clogged flue starves draft and firing.
- Check venting for proper updraft and for downdrafts or room drafts that disturb the burner and pilot.
- Have gas supply pressure and manifold pressure checked against specification — pressure work is technician work.
- Check the dip tube on the cold inlet (inside the tank top): a cracked or missing dip tube dumps cold water at the top of the tank and is the classic 'hot, then suddenly cold' cause. Replace the dip tube if it is deteriorated. → Shop the dip tube at Amazon
- If delivery is still short, the bulletin directs a partial draw test; a failed test means replace the gas control valve (thermostat). If all parts pass, the heater is undersized for peak-hour demand. → Shop the gas control valve (thermostat) at Amazon
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the dip tube.
Also tied to this fault: gas control valve (thermostat) - Shop at Amazon
Parts that commonly fix it
- dip tubeShop at Amazon
- gas control valve (thermostat)$115–$500Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.