What the 80 code means
Detected flame presence after closing solenoid valves. A few seconds after the solenoid valves close, the flame rod is still detecting flame, so the control displays 80 — it treats this as gas still burning after shutoff until proven otherwise.
Likely causes
- Solenoid valves not seating closed — gas leaking through after shutdown
- Contaminated or failed flame rod holding a false flame signal
- Loose flame rod connections (connectors 'D' and 'G') giving a false signal
How to fix it — step by step
- Turn the heater OFF and do not keep resetting it — flame reported after the valves close has to be proven false, or the leaking valve found, before the unit runs again. Rheem's diagnostic items for code 80 are the flame rod and the solenoid valves, worked through the code 51 diagnostic procedure.
- Turn power OFF. Remove and reinsert connector 'D' and connector 'G' at the flame rod terminal, then turn power ON and operate the unit — if 80 does not return, it was a loose connection or debris that is no longer present.
- Enter maintenance mode to read flame rod status and watch the burner chamber through the sight glass: cycle the unit ON-OFF three times at 10-second intervals. If flame is genuinely visible more than 5 seconds after the valves close, a solenoid valve is leaking through: replace the gas valve (manifold assembly) — a valve that does not shut off gas is replaced whole, never repaired in the field. → Shop the gas valve at Amazon
- If no flame is visible but flame rod status still reports flame after shutdown, disconnect the wire at the flame rod and repeat the test. Clean the flame rod; if 80 appears again after cleaning, replace the flame rod.
- If the false flame signal persists with the flame rod disconnected and the valves proven closed, replace the control board. All gas-side work here is qualified-technician work. → Shop the control board at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the gas valve.
Also tied to this fault: flame sensor - Shop at Amazon; control board - Shop at Amazon
Parts that commonly fix the 80 code
- gas valve$115–$500Shop at Amazon
- flame sensor$10–$60Shop at Amazon
- control board$100–$300Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.