Bradford White Water heater Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 31 problems covered.
Not sure of the code? Tap along with it
If your Bradford White Water heater blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your taps: -
Finding your model number: it is on the unit's rating plate.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
All models
| Problem | What it means | Check first | |
|---|---|---|---|
| No hot water | The pilot will light but the main burner will not come on, so the tank never heats. Chart from the Bradford… | Combination thermostat/gas valve set too low for the desired water temperature | › |
| Pilot light won't stay lit | The pilot lights but goes out as soon as the gas control knob/button is released: the thermocouple circuit is… | Poor thermocouple connection at the combination thermostat/gas valve | › |
| Rumbling or Popping Noises | Rumbling, popping or banging from a Bradford White tank while it heats is almost always sediment: minerals… | Sediment and mineral scale settled on the tank bottom, with water trapped beneath | › |
| Rumbling/popping noise | Rumbling, bubbling, surging or boiling noises from the tank during heating: water droplets bubbling up… | Lime formations or sediment collecting on the tank bottom | › |
| Smelly Water | Rotten-egg or sulfur-smelling hot water from a Bradford White tank is hydrogen sulfide gas made inside the… | Sulfate-reducing bacteria in the tank reacting with sulfate in the supply water | › |
| Water Too Hot | Water that is too hot from a Bradford White tank is a scald hazard first and a fault second. Start with the… | Thermostat simply set too high — many tanks are factory-set near 140F, above the | › |
| Won't Turn On | Bradford White sells the same dead-heater symptom in three different machines, and the brand-general page has… | Electric: tripped breaker, or the high-limit (ECO) opened after an overheat caused by a | › |
ICON System (power vent / power direct vent / fan assisted)
| Problem | What it means | Check first | |
|---|---|---|---|
| 2 flashes | Pressure switch not working - closed position: the pressure switch is stuck/welded closed when it should be… | Pressure switch tubing or ports blocked/kinked giving a false reading | › |
| 3 flashes | Pressure switch or temp switch stuck open: the blower runs but the proving circuit never closes, so the… | Vent blockage preventing proper vacuum | › |
| 4 flashes | High tank temperature: the thermowell temperature sensor reported tank water above the control's high limit. | Thermowell sensor out of calibration | › |
| 5 flashes | False pilot flame sensed: the control sees a pilot flame signal when there should be none. | Flame sensor shorted to ground | › |
| 6 flashes - 1 flash | Pilot failed to light: the control tried to light the pilot and the pilot did not establish. | Dirty or blocked pilot assembly | › |
| 6 flashes - 2 flashes | Pressure switch or temp switch opened during operation: the proving circuit that closed to start the burner… | Vent blockage developing under operation | › |
| 6 flashes - 3 flashes | Pilot flame extinguished: the pilot lit and the burner ran, then the pilot flame was lost. | Dirty pilot assembly weakening the pilot flame | › |
| 6 flashes - 4 flashes | False pilot flame sensed: the control sees a pilot flame signal when there should be none (second-stage… | Flame sensor shorted to ground | › |
| 7 flashes | Flammable vapor sensor / simulated resistive device fault: the control's flammable vapor sensing circuit… | Flammable vapor sensor resistance out of the 3.0-48 kOhm range | › |
| 8 flashes - 1 flash | Flammable vapor sensor out of specification, possible short: the sensor resistance fell outside the… | Flammable vapor sensor shorted or out of spec | › |
| 8 flashes - 2 flashes | Thermowell sensor damaged or unplugged: the control cannot read tank temperature from the thermowell sensor. | Thermowell sensor unplugged from the gas valve | › |
| 8 flashes - 3 flashes | Gas valve electronics fault: the control's electronics faulted. | Internal gas valve electronics failure | › |
| 8 flashes - 4 flashes | Gas valve fault detected: the control detected a fault in the gas valve. | Internal gas valve failure | › |
| Short flash once every second | Weak pilot signal on the last call for heat: the control completed the last cycle but the pilot/flame signal… | Dirty pilot assembly or oxidized flame sensor | › |
ICON System (SIT, atmospheric & direct vent)
| Problem | What it means | Check first | |
|---|---|---|---|
| 2 flashes | Weak pilot signal detected: the SIT ICON control, powered by thermopile millivolts from the standing pilot… | Pilot flame weak or not heating the thermopile properly (typical output should climb to | › |
| 4 flashes | High tank temperature: the SIT ICON control shut down because tank temperature exceeded the setpoint. | Tank temperature genuinely above setpoint - control operation fault | › |
| 5 flashes | Gas valve fault: the SIT ICON control detected a fault in the gas valve itself. | Internal gas valve/control fault | › |
ICON System V1 (atmospheric vent)
| Problem | What it means | Check first | |
|---|---|---|---|
| 2 flashes | Weak pilot signal detected: the thermopile is not producing enough millivolt output from the pilot flame to… | Pilot flame weak or not enveloping the thermopile | › |
| 3 flashes | The gas valve has not seen a temperature rise in the proper amount of time after firing - the control fired… | Temperature probe (temp sensor in the gas valve cover) reading incorrectly | › |
| 4 flashes | High tank temperature: tank water temperature exceeded the control's high limit and the control shut the… | Temperature probe out of calibration reading/ controlling incorrectly | › |
| 5 flashes | Thermostat sensor fault: the temperature sensor in the gas valve cover is reading out of range or has failed. | Failed temperature sensor/probe | › |
| 6 flashes | Water leak detected by the accessory module (if installed): the leak-detection accessory sensed water, in the… | Actual plumbing or tank leak filling the drain pan/water dam | › |
| 7 flashes | Gas valve fault: the ICON gas control detected an internal fault in the gas valve/control electronics. | Gas control electronic fault | › |
| 8 flashes | Pilot remains lit while the control knob is in the OFF position: the pilot valve is stuck open, so the pilot… | Pilot valve stuck in the open position inside the gas valve | › |