Bradford White Water heater ICON System (power vent / power direct vent / fan assisted) 8 flashes - 1 flash
What it should look like on your machine
then it repeats
8 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Flammable vapor sensor out of specification, possible short: the sensor resistance fell outside the acceptable range in the short direction.
Likely causes
- Flammable vapor sensor shorted or out of spec
- Sensor harness shorted
- Gas valve sensing fault
How to fix it — step by step
- Verify no flammable vapors are present around the heater before treating this as a parts fault.
- Where the sensor lives on Bradford White ICON models: the flammable vapor sensor is at the bottom of the heater, beneath the jacket (outer) door — the metal cover that gives access to the burner chamber. It mounts on two spade terminals (not polarity-sensitive) and pulls out of its cap plug/housing; the service manual (238-50216) tests it in its Flammable Vapor Sensor Testing section.
- Power OFF, open the jacket door, and disconnect the sensor. Verify its resistance is between 3.0 and 48 kOhms: this code is the short-direction failure, so a reading collapsed toward zero condemns the sensor; a sensor in range means the short is elsewhere.
- Check the sensor harness for a short or damage — chafed insulation shorting the pair produces this code with a good sensor; replace the harness if it is damaged. → Shop the sensor harness at Amazon
- Replace parts in test order: sensor first if its resistance is out of specification, then the harness, and the gas valve (control) only if sensor and harness both prove good — its sensing circuit is the last suspect. → Shop the gas valve at Amazon
- Verify with a normal heating cycle: burner lights and runs with the 8-flashes–1-flash pattern gone. This error self-clears once the sensor resistance returns to the normal range for at least 15 seconds, so a pattern that clears itself after the repair confirms the fix.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Flammable vapor sensor.
Shop the Flammable vapor sensor at Amazon
Also tied to this fault: Sensor harness - Shop at Amazon; Gas valve - Shop at Amazon
Parts that commonly fix it
- Flammable vapor sensorShop at Amazon
- Sensor harnessShop at Amazon
- Gas valve$115–$500Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Bradford White Water heater ICON System (power vent / power direct vent / fan assisted) problems
- 8 flashes - 2 flashes
- 8 flashes - 3 flashes
- 8 flashes - 4 flashes
- Short flash once every second
- 2 flashes
- 3 flashes
- 4 flashes
- 5 flashes
- 6 flashes - 1 flash
- 6 flashes - 2 flashes
- 6 flashes - 3 flashes
- 6 flashes - 4 flashes
See all Bradford White ICON System (power vent / power direct vent / fan assisted) codes & guides →