What this problem usually means
Flammable vapor sensor / simulated resistive device fault: the control's flammable vapor sensing circuit reported a fault.
Likely causes
- Flammable vapor sensor resistance out of the 3.0-48 kOhm range
- Flammable vapors actually present near the heater
- Damaged sensor harness
How to fix it — step by step
- Safety first: verify no flammable vapors are actually present around the heater and remove any source (paint, solvents, fuel stored nearby) — the sensor's job is detecting exactly that, and a true vapor event is not a parts fault.
- Where the sensor lives on Bradford White ICON models: the flammable vapor sensor is at the bottom of the heater, beneath the jacket (outer) door — the metal cover that gives access to the burner chamber. There is a dedicated Flammable Vapor Sensor Testing section (service manual 238-50216), and the OEM sensor (415-45560-00) mounts there on two spade terminals, which are not polarity-sensitive.
- Power OFF, open the jacket door, and pull the sensor from its cap plug/housing. Verify the sensor resistance is between 3.0 and 48 kOhms (Quick Service Guide range): in range with the code still set sends you to the harness; out of range condemns the sensor. → Shop the sensor harness at Amazon
- Check the sensor harness for damage and reseat it — a damaged or shorted harness produces this fault with a good sensor, and the harness is replaced if damaged.
- Replace an out-of-range sensor: push the new sensor into its housing with its four air holes facing outward, reconnect the two spade terminals, refit the jacket door, and restore power.
- Verify with a normal heating cycle: the burner lights and runs with the 7-flash pattern gone.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Flammable vapor sensor.
Shop the Flammable vapor sensor at Amazon
Also tied to this fault: Sensor harness - Shop at Amazon
Parts that commonly fix it
- Flammable vapor sensorShop at Amazon
- Sensor harnessShop at Amazon
- Tools for this job, if you need them$15–$65
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Bradford White Water heater ICON System (power vent / power direct vent / fan assisted) problems
- 8 flashes - 1 flash
- 8 flashes - 2 flashes
- 8 flashes - 3 flashes
- 8 flashes - 4 flashes
- Short flash once every second
- 2 flashes
- 3 flashes
- 4 flashes
- 5 flashes
- 6 flashes - 1 flash
- 6 flashes - 2 flashes
- 6 flashes - 3 flashes
See all Bradford White ICON System (power vent / power direct vent / fan assisted) codes & guides →