Bradford White Water heater ICON System V1 (atmospheric vent) 8 flashes
What it should look like on your machine
then it repeats
8 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Pilot remains lit while the control knob is in the OFF position: the pilot valve is stuck open, so the pilot does not shut off with the control.
Likely causes
- Pilot valve stuck in the open position inside the gas valve
- Gas pressure problem holding the valve open
How to fix it — step by step
- Confirm the fault by eye first: turn the control knob to OFF and look through the sight glass — a pilot flame still burning with the knob at OFF is this code proven; the pilot valve inside the control is stuck open.
- Check gas pressure to the control if you have a manometer: pressure far above the rating plate can hold a valve open, and that is a supply/regulator fault, not the control.
- With pressure in specification, the pilot valve is stuck open inside the gas valve — it is internal to the control and is not a serviceable part, so the gas valve is replaced: Replace the gas valve (the ICON control at the front of the tank): knob to OFF, main gas supply OFF, tank drained, the pilot tube, thermopile and igniter connections disconnected at the control, the control unthreaded from the tank fitting by turning it with a pipe section threaded into its inlet — never a wrench on the control body. Fit the new control with approved pipe joint compound on the tank fitting, reconnect everything, turn the gas on and leak-test the connections, fill the tank completely before relighting, and relight per the label. → Shop the gas valve at Amazon
- Until it is replaced, shut the main gas supply to the heater off — a pilot that cannot be turned off is not a heater to leave in service.
- If you hand it over, tell the technician: 8 flashes — pilot stays lit with the control knob at OFF; the pilot valve is stuck open in the control.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Gas valve.
Parts that commonly fix it
- Gas valve$115–$500Shop at Amazon
- Tools for this job, if you need them$10–$20
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.