Bradford White ICON System (power vent / power direct vent / fan assisted) Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 14 problems covered.
Not sure of the code? Tap along with it
If your Bradford White Water heater blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your taps: -
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Problem | What it means | Check first | |
|---|---|---|---|
| 2 flashes | Pressure switch not working - closed position: the pressure switch is stuck/welded closed when it should be… | Pressure switch tubing or ports blocked/kinked giving a false reading | › |
| 3 flashes | Pressure switch or temp switch stuck open: the blower runs but the proving circuit never closes, so the… | Vent blockage preventing proper vacuum | › |
| 4 flashes | High tank temperature: the thermowell temperature sensor reported tank water above the control's high limit. | Thermowell sensor out of calibration | › |
| 5 flashes | False pilot flame sensed: the control sees a pilot flame signal when there should be none. | Flame sensor shorted to ground | › |
| 6 flashes - 1 flash | Pilot failed to light: the control tried to light the pilot and the pilot did not establish. | Dirty or blocked pilot assembly | › |
| 6 flashes - 2 flashes | Pressure switch or temp switch opened during operation: the proving circuit that closed to start the burner… | Vent blockage developing under operation | › |
| 6 flashes - 3 flashes | Pilot flame extinguished: the pilot lit and the burner ran, then the pilot flame was lost. | Dirty pilot assembly weakening the pilot flame | › |
| 6 flashes - 4 flashes | False pilot flame sensed: the control sees a pilot flame signal when there should be none (second-stage… | Flame sensor shorted to ground | › |
| 7 flashes | Flammable vapor sensor / simulated resistive device fault: the control's flammable vapor sensing circuit… | Flammable vapor sensor resistance out of the 3.0-48 kOhm range | › |
| 8 flashes - 1 flash | Flammable vapor sensor out of specification, possible short: the sensor resistance fell outside the… | Flammable vapor sensor shorted or out of spec | › |
| 8 flashes - 2 flashes | Thermowell sensor damaged or unplugged: the control cannot read tank temperature from the thermowell sensor. | Thermowell sensor unplugged from the gas valve | › |
| 8 flashes - 3 flashes | Gas valve electronics fault: the control's electronics faulted. | Internal gas valve electronics failure | › |
| 8 flashes - 4 flashes | Gas valve fault detected: the control detected a fault in the gas valve. | Internal gas valve failure | › |
| Short flash once every second | Weak pilot signal on the last call for heat: the control completed the last cycle but the pilot/flame signal… | Dirty pilot assembly or oxidized flame sensor | › |