Bradford White ICON System (power vent / power direct vent / fan assisted) Common Problems

Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 14 problems covered.

Not sure of the code? Tap along with it

If your Bradford White Water heater blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.

Your taps: -

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

ProblemWhat it meansCheck first
2 flashesPressure switch not working - closed position: the pressure switch is stuck/welded closed when it should be…Pressure switch tubing or ports blocked/kinked giving a false reading›
3 flashesPressure switch or temp switch stuck open: the blower runs but the proving circuit never closes, so the…Vent blockage preventing proper vacuum›
4 flashesHigh tank temperature: the thermowell temperature sensor reported tank water above the control's high limit.Thermowell sensor out of calibration›
5 flashesFalse pilot flame sensed: the control sees a pilot flame signal when there should be none.Flame sensor shorted to ground›
6 flashes - 1 flashPilot failed to light: the control tried to light the pilot and the pilot did not establish.Dirty or blocked pilot assembly›
6 flashes - 2 flashesPressure switch or temp switch opened during operation: the proving circuit that closed to start the burner…Vent blockage developing under operation›
6 flashes - 3 flashesPilot flame extinguished: the pilot lit and the burner ran, then the pilot flame was lost.Dirty pilot assembly weakening the pilot flame›
6 flashes - 4 flashesFalse pilot flame sensed: the control sees a pilot flame signal when there should be none (second-stage…Flame sensor shorted to ground›
7 flashesFlammable vapor sensor / simulated resistive device fault: the control's flammable vapor sensing circuit…Flammable vapor sensor resistance out of the 3.0-48 kOhm range›
8 flashes - 1 flashFlammable vapor sensor out of specification, possible short: the sensor resistance fell outside the…Flammable vapor sensor shorted or out of spec›
8 flashes - 2 flashesThermowell sensor damaged or unplugged: the control cannot read tank temperature from the thermowell sensor.Thermowell sensor unplugged from the gas valve›
8 flashes - 3 flashesGas valve electronics fault: the control's electronics faulted.Internal gas valve electronics failure›
8 flashes - 4 flashesGas valve fault detected: the control detected a fault in the gas valve.Internal gas valve failure›
Short flash once every secondWeak pilot signal on the last call for heat: the control completed the last cycle but the pilot/flame signal…Dirty pilot assembly or oxidized flame sensor›

All Bradford White water heater models & codes →