What this problem usually means
Gas valve fault: the SIT ICON control detected a fault in the gas valve itself.
Likely causes
- Internal gas valve/control fault
How to fix it — step by step
- Turn the control to OFF and wait for the LED to go out, then relight and turn the knob back to the setpoint.
- If the burner fires, the code will clear after 5 minutes — let it; a code that clears and stays clear after the documented reset was a transient control fault.
- If the problem persists, the SIT ICON control at the front of the tank has an internal fault and is replaced: Replace the gas valve (the ICON control at the front of the tank): knob to OFF, main gas supply OFF, tank drained, the pilot tube, thermopile and igniter connections disconnected at the control, the control unthreaded from the tank fitting by turning it with a pipe section threaded into its inlet — never a wrench on the control body. Fit the new control with approved pipe joint compound on the tank fitting, reconnect everything, turn the gas on and leak-test the connections, fill the tank completely before relighting, and relight per the label. → Shop the gas valve at Amazon
- Prove a full heating cycle with no returning code.
- If you hand it over, tell the technician: 5 flashes persisting after the OFF-and-relight reset — SIT ICON gas valve fault.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Gas valve.
Parts that commonly fix it
- Gas valve$115–$500Shop at Amazon
- Tools for this job, if you need them$10–$20
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Bradford White Water heater ICON System (SIT, atmospheric & direct vent) problems
See all Bradford White ICON System (SIT, atmospheric & direct vent) codes & guides →