Bradford White Water heater ICON System (power vent / power direct vent / fan assisted) 6 flashes - 3 flashes
What it should look like on your machine
then it repeats
6 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Pilot flame extinguished: the pilot lit and the burner ran, then the pilot flame was lost.
Likely causes
- Dirty pilot assembly weakening the pilot flame
- Loose connection at the gas valve interrupting the pilot circuit
How to fix it — step by step
- Inspect and clean the pilot assembly: The pilot assembly is behind the burner access door at the base of the tank, its thermopile/flame-sensor leads running up to the gas control at the front of the tank — a pilot flame weakened by dirt lifts off the sensor mid-cycle and produces exactly this code.
- Check the connection at the gas valve and reseat it — an intermittent connection interrupts the pilot circuit the same way a dying flame does, so the lead and its terminals are cleaned and tightened before parts are condemned.
- Run a call and watch the pilot through the sight glass across a full cycle: a flame that shrinks or lifts as the main burner runs is a pilot/gas problem; a steady flame with the code returning is the sensor or its circuit.
- Replace the pilot assembly if the flame still drops out; replace the gas valve if a good pilot assembly does not hold: Replace the gas valve (the ICON control at the front of the tank): knob to OFF, main gas supply OFF, tank drained, the pilot tube, thermopile and igniter connections disconnected at the control, the control unthreaded from the tank fitting by turning it with a pipe section threaded into its inlet — never a wrench on the control body. Fit the new control with approved pipe joint compound on the tank fitting, reconnect everything, turn the gas on and leak-test the connections, fill the tank completely before relighting, and relight per the label. → Shop the pilot assembly at Amazon → Shop the gas valve at Amazon
- If you hand it over, tell the technician: 6 flashes–3 — pilot flame extinguished after running — and what the pilot flame did across the cycle you watched.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Pilot assembly.
Shop the Pilot assembly at Amazon
Also tied to this fault: Gas valve - Shop at Amazon
Parts that commonly fix it
- Pilot assembly$30–$120Shop at Amazon
- Gas valve$115–$500Shop at Amazon
- Tools for this job, if you need them$10–$20
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Bradford White Water heater ICON System (power vent / power direct vent / fan assisted) problems
- 6 flashes - 4 flashes
- 7 flashes
- 8 flashes - 1 flash
- 8 flashes - 2 flashes
- 8 flashes - 3 flashes
- 8 flashes - 4 flashes
- Short flash once every second
- 2 flashes
- 3 flashes
- 4 flashes
- 5 flashes
- 6 flashes - 1 flash
See all Bradford White ICON System (power vent / power direct vent / fan assisted) codes & guides →