Bradford White Water heater ICON System (power vent / power direct vent / fan assisted) 4 flashes

What it should look like on your machine

then it repeats

4 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

High tank temperature: the thermowell temperature sensor reported tank water above the control's high limit.

Likely causes

  1. Thermowell sensor out of calibration
  2. Faulty gas valve overheating the tank

How to fix it — step by step

  1. Confirm actual tank temperature with a thermometer at a hot faucet against the setpoint — this splits the code: water genuinely overheated is a control fault; water at setpoint with the code present is a sensing fault.
  2. Check the temp probe ohms against the sensor temperature chart in the service guide: the probe is the thermowell sensor screwed into the tank, its lead plugged into the gas control at the front of the tank. Unplug it and measure — a reading off the chart for the measured water temperature condemns the thermowell sensor. → Shop the thermowell at Amazon
  3. Replace the thermowell if the sensor reads out of specification: power and gas off, tank drained below the sensor level (or fully), the old sensor unthreaded from the tank, the new one sealed and threaded in, lead reconnected.
  4. Replace the gas valve if the control is genuinely overheating the water (sensor proven good, burner running past setpoint): Replace the gas valve (the ICON control at the front of the tank): knob to OFF, main gas supply OFF, tank drained, the pilot tube, thermopile and igniter connections disconnected at the control, the control unthreaded from the tank fitting by turning it with a pipe section threaded into its inlet — never a wrench on the control body. Fit the new control with approved pipe joint compound on the tank fitting, reconnect everything, turn the gas on and leak-test the connections, fill the tank completely before relighting, and relight per the label. → Shop the gas valve at Amazon
  5. Prove two heating cycles stopping at setpoint with no 4-flash code.
  6. If you hand it over, tell the technician: 4 flashes — high tank temperature — and whether the water was actually over setpoint or the sensor was misreading.
  7. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.