Bradford White Water heater ICON System (SIT, atmospheric & direct vent) 2 flashes

What it should look like on your machine

then it repeats

2 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Weak pilot signal detected: the SIT ICON control, powered by thermopile millivolts from the standing pilot, is receiving a weak pilot signal.

Likely causes

  1. Pilot flame weak or not heating the thermopile properly (typical output should climb to about 300-500 mV)
  2. Loose thermopile wire connections at the front of the gas valve

How to fix it — step by step

  1. Verify the pilot is lit and stays lit.
  2. Measure thermopile output with a voltmeter at the wires plugged into the front of the control - with the pilot lit it should steadily climb to approximately 300-500 mV.
  3. Check the wire connections at the gas valve and reseat them.
  4. Replace the pilot assembly if output stays low with a good flame; replace the gas valve if a good pilot assembly does not restore the signal. → Shop the pilot assembly at Amazon → Shop the gas valve at Amazon
  5. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Bradford White Water heater ICON System (SIT, atmospheric & direct vent) problems

See all Bradford White ICON System (SIT, atmospheric & direct vent) codes & guides →