Bradford White Water heater No hot water
What this problem usually means
The pilot will light but the main burner will not come on, so the tank never heats. Chart from the Bradford White Defender service manual (White Rodgers/Robertshaw mechanical gas valve models); a pilot that will not light at all has the same first checks - no incoming gas or low gas pressure, knob in the wrong position, knob not fully depressed, obstructed/kinked pilot orifice or tube, pilot electrode not sparking, or a failed piezo igniter.
Likely causes
- Combination thermostat/gas valve set too low for the desired water temperature
- Thermostat already satisfied - tank is at temperature
- Insufficient gas supply or low gas pressure
- Combination thermostat/gas valve has a wide differential or is out of calibration
How to fix it — step by step
- Check the temperature dial on the combination thermostat/gas valve - the control mounted on the front of the tank - and raise it if it is set too low; confirm the tank is not simply already at temperature, which produces the same 'no hot water at the burner' picture with nothing faulty.
- Turn on the gas supply and check line pressure if the burner will not fire.
- Review the lighting instructions: set the gas control knob to the correct position and fully depress it when lighting the pilot, and confirm the pilot is actually lit by looking through the sight glass at the base of the tank.
- Work the pilot side, which lives inside the burner compartment at the base of the tank behind the outer burner door: clean, repair or replace an obstructed pilot orifice/tube, verify the electrode position (replace the pilot assembly if it will not spark correctly) and replace a failed piezo igniter (the push-button igniter on the gas control). → Shop the pilot assembly at Amazon → Shop the piezo igniter at Amazon
- Test the thermocouple before condemning the valve: the service procedure is a closed-circuit millivolt test at the back of the gas valve - 10 millivolts or higher (White Rodgers control) or 13 or higher (Robertshaw) means the thermocouple is doing its job. If the pilot lights and holds, the thermocouple tests good, gas supply and settings are correct but the burner still will not come on, the combination thermostat/gas valve is out of calibration - replace it, and verify the burner fires on a call for heat. → Shop the combination thermostat/gas valve at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the Pilot assembly.
Shop the Pilot assembly at Amazon
Also tied to this fault: Piezo igniter - Shop at Amazon; Combination thermostat/gas valve - Shop at Amazon
Parts that commonly fix it
- Pilot assembly$30–$120Shop at Amazon
- Piezo igniterShop at Amazon
- Combination thermostat/gas valve$115–$500Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.