Bradford White Water heater ICON System (power vent / power direct vent / fan assisted) 8 flashes - 2 flashes
What it should look like on your machine
then it repeats
8 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Thermowell sensor damaged or unplugged: the control cannot read tank temperature from the thermowell sensor.
Likely causes
- Thermowell sensor unplugged from the gas valve
- Thermowell sensor damaged or reading out of range
How to fix it — step by step
- Check the temp probe connection at the gas valve and reseat it if unplugged.
- Check the temp probe ohms against the sensor temperature chart.
- Replace the gas valve (the thermowell/control assembly per the parts list) if the sensor is damaged. → Shop the gas valve at Amazon
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Gas valve.
Parts that commonly fix it
- Gas valve$115–$500Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Bradford White Water heater ICON System (power vent / power direct vent / fan assisted) problems
- 8 flashes - 3 flashes
- 8 flashes - 4 flashes
- Short flash once every second
- 2 flashes
- 3 flashes
- 4 flashes
- 5 flashes
- 6 flashes - 1 flash
- 6 flashes - 2 flashes
- 6 flashes - 3 flashes
- 6 flashes - 4 flashes
- 7 flashes
See all Bradford White ICON System (power vent / power direct vent / fan assisted) codes & guides →