Bradford White Water heater ICON System V1 (atmospheric vent) 3 flashes
What it should look like on your machine
then it repeats
3 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
The gas valve has not seen a temperature rise in the proper amount of time after firing - the control fired but tank temperature did not rise as expected.
Likely causes
- Temperature probe (temp sensor in the gas valve cover) reading incorrectly
- Water flowing through the tank carrying heat away during the test period
- Faulty gas valve cover with temp probe
How to fix it — step by step
- Locate the suspect part: the temperature probe (temp sensor) lives in the gas valve cover of the ICON gas control — the control mounted on the front of the tank, low down, with the knob/status LED on its face and the probe extending from its cover into the tank well. Access is external: the control is on the outside of the tank and the probe test is done at the control — the tank is not opened and nothing is drained for the test itself.
- Check the temp probe ohms against the sensor temperature chart (compare at the actual tank temperature): in-specification ohms mean the probe is reading correctly and the fault moves to the control electronics/flow branch below; out-of-specification ohms condemn the gas valve cover with temp probe. → Shop the gas valve cover with temp probe at Amazon
- Verify water is not flowing through the heater while the control is timing the temperature rise — flow carrying heat away during the test period produces this code with a good probe, so prove no-flow first.
- Replace the gas valve cover with temp probe if the probe reads out of specification: power/knob off per the control's service instructions, remove the cover with the probe, fit the new cover/probe assembly, reconnect, and prove a full heating cycle watching for a normal temperature rise and shut-off.
- Tell the technician: 3 flashes, the probe resistance and the chart value at the measured tank temperature, and the actual water temperature. What this job involves: the probe/cover swap is external control work; a full gas valve swap adds gas-line disconnection, draining and leak testing — licensed gas work in most jurisdictions.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Gas valve cover with temp probe.
Parts that commonly fix it
- Gas valve cover with temp probe$115–$500Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.