Bradford White Water heater ICON System V1 (atmospheric vent) 7 flashes

What it should look like on your machine

then it repeats

7 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Gas valve fault: the ICON gas control detected an internal fault in the gas valve/control electronics.

Likely causes

  1. Gas control electronic fault
  2. Control wet or physically damaged

How to fix it — step by step

  1. Reset the gas valve: turn the control off, wait for the LED to go out, then relight and return the knob to the setpoint.
  2. Check the control for the one external cause first: the ICON control at the front of the tank must be dry and undamaged — a control that has been wet (leaking fitting above it, flooded floor) or physically knocked can fault internally, and that history matters.
  3. If the problem persists after the reset, the control's electronics have failed and the valve is replaced: Replace the gas valve (the ICON control at the front of the tank): knob to OFF, main gas supply OFF, tank drained, the pilot tube, thermopile and igniter connections disconnected at the control, the control unthreaded from the tank fitting by turning it with a pipe section threaded into its inlet — never a wrench on the control body. Fit the new control with approved pipe joint compound on the tank fitting, reconnect everything, turn the gas on and leak-test the connections, fill the tank completely before relighting, and relight per the label. → Shop the gas valve at Amazon
  4. Prove a full heating cycle with normal ignition and no 7-flash code.
  5. If you hand it over, tell the technician: 7 flashes persisting after the documented reset — ICON gas control internal fault.
  6. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017
  • Gas valve$115–$500Shop at Amazon
  • Tools for this job, if you need them$10–$20

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.