Bradford White Water heater ICON System (power vent / power direct vent / fan assisted) Short flash once every second
What this problem usually means
Weak pilot signal on the last call for heat: the control completed the last cycle but the pilot/flame signal was marginal.
Likely causes
- Dirty pilot assembly or oxidized flame sensor
- Weak pilot flame
- Gas valve sensing a marginal signal
How to fix it — step by step
- Inspect and clean the pilot assembly: The pilot assembly is behind the burner access door at the base of the tank, its thermopile/flame-sensor leads running up to the gas control at the front of the tank — remove the access door, brush and blow out the pilot, and clear the pilot orifice; a dirty pilot is the documented first cause of a marginal signal.
- Check continuity on the flame sensor and inspect its lead for a short or a corroded terminal at the gas control; reseat the connection.
- Run a call for heat and watch the signal: a pilot that lights cleanly and holds with a strong flame after cleaning was a maintenance fault, and the code clears.
- Replace the pilot assembly if cleaning does not restore a strong signal (leads off at the control, mounting screws out, new assembly fitted with the sensor in the same flame position); replace the gas valve if a good pilot assembly does not clear it: Replace the gas valve (the ICON control at the front of the tank): knob to OFF, main gas supply OFF, tank drained, the pilot tube, thermopile and igniter connections disconnected at the control, the control unthreaded from the tank fitting by turning it with a pipe section threaded into its inlet — never a wrench on the control body. Fit the new control with approved pipe joint compound on the tank fitting, reconnect everything, turn the gas on and leak-test the connections, fill the tank completely before relighting, and relight per the label. → Shop the pilot assembly at Amazon → Shop the gas valve at Amazon
- If you hand it over, tell the technician: short flash every second — weak pilot signal on the last call — with the pilot assembly already cleaned.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Pilot assembly.
Shop the Pilot assembly at Amazon
Also tied to this fault: Gas valve - Shop at Amazon
Parts that commonly fix it
- Pilot assembly$30–$120Shop at Amazon
- Gas valve$115–$500Shop at Amazon
- Tools for this job, if you need them$10–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Bradford White Water heater ICON System (power vent / power direct vent / fan assisted) problems
- 2 flashes
- 3 flashes
- 4 flashes
- 5 flashes
- 6 flashes - 1 flash
- 6 flashes - 2 flashes
- 6 flashes - 3 flashes
- 6 flashes - 4 flashes
- 7 flashes
- 8 flashes - 1 flash
- 8 flashes - 2 flashes
- 8 flashes - 3 flashes
See all Bradford White ICON System (power vent / power direct vent / fan assisted) codes & guides →