Bradford White Water heater ICON System V1 (atmospheric vent) 5 flashes

What it should look like on your machine

then it repeats

5 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Thermostat sensor fault: the temperature sensor in the gas valve cover is reading out of range or has failed.

Likely causes

  1. Failed temperature sensor/probe
  2. Faulty gas valve electronics reading the sensor

How to fix it — step by step

  1. Locate the suspect part: the temperature probe (temp sensor) lives in the gas valve cover of the ICON gas control — the control mounted on the front of the tank, low down, with the knob/status LED on its face and the probe extending from its cover into the tank well. Access is external: the control is on the outside of the tank and the probe test is done at the control — the tank is not opened and nothing is drained for the test itself.
  2. Check the temp probe ohms against the sensor temperature chart (compare at the actual tank temperature): in-specification ohms mean the probe is reading correctly and the fault moves to the control electronics/flow branch below; out-of-specification ohms condemn the gas valve cover with temp probe. → Shop the gas valve cover with temp probe at Amazon
  3. Check the actual water temperature with a thermometer to confirm the sensor reading is wrong — normal water temperature with a sensor-fault code proves the probe/control sensing, not an overheat.
  4. Replace the gas valve cover with temp probe if the probe reads out of specification: power/knob off per the control's service instructions, remove the cover with the probe, fit the new cover/probe assembly, reconnect, and prove a full heating cycle watching for a normal temperature rise and shut-off.
  5. Tell the technician: 5 flashes, the probe resistance and the chart value at the measured tank temperature, and the actual water temperature. What this job involves: the probe/cover swap is external control work; a full gas valve swap adds gas-line disconnection, draining and leak testing — licensed gas work in most jurisdictions.
  6. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017
  • Gas valve cover with temp probe$115–$500Shop at Amazon
  • Tools for this job, if you need them$10–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.