Bradford White Water heater ICON System (power vent / power direct vent / fan assisted) 3 flashes

What it should look like on your machine

then it repeats

3 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Pressure switch or temp switch stuck open: the blower runs but the proving circuit never closes, so the control will not fire the burner.

Likely causes

  1. Vent blockage preventing proper vacuum
  2. Blower not spinning up to speed
  3. Pressure switch tubing/ports blocked or kinked
  4. Faulty pressure switch, temp switch, blower assembly or gas valve

How to fix it — step by step

  1. Check the vent for blockage and clear it — the vent termination and the full run; a blocked vent means the blower can never make vacuum.
  2. Verify the blower is spinning up to speed: the blower is the fan assembly on top of the tank; it should come up to a strong, steady speed on a call. A blower that hums, starts slowly or stalls is the fault, ahead of any switch.
  3. The pressure switch is mounted at the blower housing on top of the tank, with vinyl tubing to the blower outlet; the temp (vent limit) switch is in the same proving circuit at the blower/vent. Both are reached with the top cover off.
  4. Measure vacuum on the pressure switch with a manometer during the call and inspect the tubing and ports: vacuum at or above the switch's rating with the circuit still open condemns a switch; low vacuum sends you back to the vent and blower.
  5. Bypass the pressure switch and temp switch for testing only to isolate the failed device — never leave a bypass in place.
  6. Replace the failed component in order: pressure switch (tubing and wires off, screws out, rating matched), temp switch (at the blower/vent, wires transferred), blower assembly (power off, vent and wiring disconnected, assembly off the tank top), or gas valve (the control at the front of the tank — replaced only when the proving circuit tests good end to end and the control still will not fire). → Shop the blower assembly at Amazon → Shop the gas valve at Amazon
  7. Prove a full heating cycle with the circuit proving and no 3-flash code.
  8. If you hand it over, tell the technician: 3 flashes — proving circuit never closes — and the vacuum reading you measured at the switch.
  9. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.