Bradford White Water heater ICON System (power vent / power direct vent / fan assisted) 5 flashes
What it should look like on your machine
then it repeats
5 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
False pilot flame sensed: the control sees a pilot flame signal when there should be none.
Likely causes
- Flame sensor shorted to ground
- Pilot valve stuck open in the gas valve
How to fix it — step by step
- Check for a flame sensor short to ground: The pilot assembly is behind the burner access door at the base of the tank, its thermopile/flame-sensor leads running up to the gas control at the front of the tank. Inspect the sensor lead end to end for chafing against the burner or cabinet, and test the lead for continuity to ground — a grounded lead fakes a flame signal with no flame present, and it is repaired or the pilot assembly replaced. → Shop the pilot assembly at Amazon
- If the sensor circuit is sound, look at the pilot itself with the control off: a pilot flame that will not shut off means the pilot valve is stuck open — the gas valve is stuck open and is replaced: Replace the gas valve (the ICON control at the front of the tank): knob to OFF, main gas supply OFF, tank drained, the pilot tube, thermopile and igniter connections disconnected at the control, the control unthreaded from the tank fitting by turning it with a pipe section threaded into its inlet — never a wrench on the control body. Fit the new control with approved pipe joint compound on the tank fitting, reconnect everything, turn the gas on and leak-test the connections, fill the tank completely before relighting, and relight per the label. Until then, shut the main gas supply to the heater off. → Shop the gas valve at Amazon
- Prove a full cycle in which the control sees no flame signal at standby and the pilot lights only on a call.
- If you hand it over, tell the technician: 5 flashes — false pilot flame sensed — and whether the sensor lead tested shorted to ground.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Pilot assembly.
Shop the Pilot assembly at Amazon
Also tied to this fault: Gas valve - Shop at Amazon
Parts that commonly fix it
- Pilot assembly$30–$120Shop at Amazon
- Gas valve$115–$500Shop at Amazon
- Tools for this job, if you need them$10–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Bradford White Water heater ICON System (power vent / power direct vent / fan assisted) problems
- 6 flashes - 1 flash
- 6 flashes - 2 flashes
- 6 flashes - 3 flashes
- 6 flashes - 4 flashes
- 7 flashes
- 8 flashes - 1 flash
- 8 flashes - 2 flashes
- 8 flashes - 3 flashes
- 8 flashes - 4 flashes
- Short flash once every second
- 2 flashes
- 3 flashes
See all Bradford White ICON System (power vent / power direct vent / fan assisted) codes & guides →