Bradford White Water heater Pilot light won't stay lit
What this problem usually means
The pilot lights but goes out as soon as the gas control knob/button is released: the thermocouple circuit is not holding the pilot valve open. Chart from the Bradford White Defender service manual (White Rodgers/Robertshaw mechanical gas valve models).
Likely causes
- Poor thermocouple connection at the combination thermostat/gas valve
- Thermocouple not fully engaged in the pilot assembly bracket
- Pilot flame not fully enveloping the thermocouple bulb
- Weak or defective thermocouple
- Open ECO in the combination thermostat/gas valve
- Defective magnet in the combination thermostat/gas valve
- Resettable thermal switch has opened
How to fix it — step by step
- Check the thermocouple connection at the combination thermostat/gas valve - proper tightness is finger tight plus a 1/4 turn.
- Access: the pilot bracket, thermocouple tip and thermal switch live behind the doors at the base of the tank - turn the gas control knob to OFF and close the manual gas shut-off valve, remove the outer door, then the inner door panel behind it (the resettable thermal switch is mounted on that inner door). The burner assembly slides out on its tray if it has to come out for the orifice cleaning below
- Inspect the thermocouple to ensure it is fully engaged into the pilot bracket.
- Clean the pilot orifice and adjust the thermocouple tip so it is fully enveloped by the pilot flame.
- Test the thermocouple and replace it if its millivolt output is weak. → Shop the thermocouple at Amazon
- Determine why the resettable thermal switch opened, then reset it by depressing the button on the switch located on the inner door.
- Check ECO continuity and magnet operation - if either has failed, replace the combination thermostat/gas valve. → Shop the combination thermostat/gas valve at Amazon
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Thermocouple.
Shop the Thermocouple at Amazon
Also tied to this fault: Combination thermostat/gas valve - Shop at Amazon
Parts that commonly fix it
- ThermocoupleShop at Amazon
- Combination thermostat/gas valve$115–$500Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.