Amana AVZC20 series Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 20 codes covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| E12 | Shown as PCB LED display 12 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | High electrical noise on the control circuit | › |
| E13 | Shown as PCB LED display 13 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Blocked/restricted condenser coil | › |
| E15 | Shown as PCB LED display 15 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Low refrigerant charge / refrigerant leak | › |
| E17 | Shown as PCB LED display 17 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Compressor wire lost phase / broken compressor lead | › |
| E18 | Shown as PCB LED display 18 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Faulty outdoor control board (internal failure) | › |
| E19 | Shown as PCB LED display 19 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Outdoor fan motor not connected properly | › |
| E20 | Shown as PCB LED display 20 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Outdoor EEV coil not connected at the control board | › |
| E21 | Shown as PCB LED display 21 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Thermistors inoperable or improperly connected | › |
| E22 | Shown as PCB LED display 22 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Low refrigerant charge | › |
| E23 | Shown as PCB LED display 23 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Discharge thermistor inoperable | › |
| E24 | Shown as PCB LED display 24 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Inoperable / failed high pressure switch (open) | › |
| E25 | Shown as PCB LED display 25 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Outdoor air thermistor open | › |
| E26 | Shown as PCB LED display 26 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Low pressure sensor inoperable | › |
| E27 | Shown as PCB LED display 27 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Outdoor defrost thermistor inoperable (open or shorted) | › |
| E28 | Shown as PCB LED display 28 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Outdoor coil thermistor inoperable (open or shorted) | › |
| E29 | Shown as PCB LED display 29 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Liquid line thermistor inoperable (open or shorted) | › |
| E30 | Shown as PCB LED display 30 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Wiring to the outdoor control board disconnected | › |
| E31 | Shown as PCB LED display 31 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Improper ground / loose ground screws or lugs | › |
| E32 | Shown as PCB LED display 32 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Ambient air conditions too high | › |
| E34 | Shown as PCB LED display 34 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Current spike in the power supply | › |
All Amana heat pump models & codes →
Looking for a part?
Once you know the part you need, browse Amana AVZC20 series replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.