Amana Heat pump AVZC20 series E31 Error Code
What the E31 code means
Shown as PCB LED display 31 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E31, this is the AVZC20 outdoor chart's 'HI LEAK CURRENT.' The thermostat message says the control has detected high leakage current (high voltage). Probable causes listed are noise, an improper ground, or a faulty compressor, with corrective actions to check ground screws/lugs and wiring and repair or replace if needed, and to check the compressor and repair or replace if needed. Leakage current is a shock and safety concern, not a comfort fault - a unit setting E31 should stay off until the ground path and compressor insulation are proven.
Likely causes
- Improper ground / loose ground screws or lugs
- Faulty compressor (winding leakage to ground)
- Electrical noise
How to fix it — step by step
- Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E31) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
- Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
- Locate the part: start at the ground screws/lugs and ground wiring in the AVZC20 outdoor unit's control compartment (access panel off), then the compressor in the base of the unit, whose windings are the other named leakage source; the code is read on the outdoor control board's LED display.
- Test: with power off, inspect and tighten-check the ground screws, lugs and bonding wiring - a loose or corroded ground is the chart's first cause. Then test the compressor windings for resistance to ground (a megohm/insulation test): any low resistance from a winding to the compressor shell proves the compressor is leaking to ground, while a clean insulation test with a proven ground path points back to noise or the control.
- End at the pinpoint: repair the ground path if it was faulty; a compressor proven to leak to ground is the pinpoint and its replacement is sealed-system, EPA-certified work. Do not run the unit with E31 active - this is technician work.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the fault is internal - there is no documented owner fix beyond the steps above. If you're not comfortable taking it apart yourself, a repair shop is the next step.
Parts that commonly fix the E31 code
No specific replacement part is documented for this fault. If the checks above do not clear it, your heat pump likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.