Amana Heat pump AVZC20 series E17 Error Code

What the E17 code means

Shown as PCB LED display 17 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E17, this is the AVZC20 outdoor chart's 'COMPRESSOR FAIL.' The thermostat message says the equipment is experiencing frequent compressor faults. Probable causes listed are a stop valve not completely open, the compressor wire having lost a phase, or compressor motor failure, with corrective actions to check the stop valve is full open, check the wire between the control board and the compressor, and inspect the compressor motor for proper function and replace it if necessary. On this inverter unit the compressor is driven by the outdoor control, so wiring and drive faults must be separated from a failed compressor motor.

Likely causes

  1. Compressor wire lost phase / broken compressor lead
  2. Compressor motor failure
  3. Stop valve not completely open

How to fix it — step by step

  1. Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E17) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
  2. Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
  3. Locate the part: the compressor sits in the base of the AVZC20 outdoor unit, wired from the inverter outdoor control board in the control compartment; both are reached by removing the unit's access panels, and the code is read on that board's LED display.
  4. Test: with power off, inspect and continuity-check each lead between the control board and the compressor - an open lead proves the lost-phase wiring cause. Then ohm the compressor motor windings at its terminals: windings that are open, shorted or grossly unequal prove compressor motor failure, while balanced windings with good leads point back to the inverter control's compressor drive.
  5. End at the pinpoint: repair/replace the faulty compressor lead, or replace the Control board if its drive output is proven faulty; a compressor motor that tests failed is the pinpoint and its replacement is sealed-system, EPA-certified technician work only.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E17 code

  • Control boardShop at Amazon
  • Tools for this job, if you need them$15–$65

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.