What the E28 code means
Shown as PCB LED display 28 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E28, this is the AVZC20 outdoor chart's 'COIL TEMP FAIL2,' the companion to E27. The thermostat message says the control has detected that the outdoor coil temperature sensor is out of range, the probable cause listed is an outdoor coil thermistor inoperable or not properly connected, and the corrective action is to check the connection to the outdoor coil thermistor and repair or replace if needed. The coil temperature reading feeds the inverter control's heating and defrost calculations, so a failed sensor distorts both capacity and defrost behaviour.
Likely causes
- Outdoor coil thermistor inoperable (open or shorted)
- Coil thermistor not properly connected
- Coil thermistor out of range
How to fix it — step by step
- Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E28) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
- Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
- Locate the part: the outdoor coil thermistor is clipped to the outdoor coil tubing on the AVZC20 outdoor unit, with its lead plugged into the outdoor control board in the control compartment, where E28 is read on the board's LED display; do not confuse it with the separate defrost thermistor covered by E27.
- Test: with power off, reseat the coil thermistor's connector at the board, then measure the thermistor's resistance and compare it with the coil's actual temperature - OL proves an open sensor/lead, near-zero a short, and a value inconsistent with the measured coil temperature proves an out-of-range sensor. → Shop the thermistor at Amazon
- End at the fix: repair the connection or replace the Thermistor as condemned, restore power and run heating and cooling calls to confirm E28 clears; if a verified-good thermistor still sets E28, the pinpointed cause is the Control board's sensor input. → Shop the control board at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the Thermistor.
Also tied to this fault: Control board - Shop at Amazon
Parts that commonly fix the E28 code
- Thermistor$25–$80Shop at Amazon
- Control boardShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.