Amana Heat pump AVZC20 series E27 Error Code
What the E27 code means
Shown as PCB LED display 27 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E27, this is the AVZC20 outdoor chart's 'COIL TEMP FAIL1.' The thermostat message says the control detects that the outdoor defrost sensor is out of range, the probable cause listed is an outdoor defrost thermistor inoperable or not properly connected, and the corrective action is to check the connection to the outdoor defrost thermistor and repair as needed. This is the sensor the control watches to start and end defrost in heating, so an out-of-range reading undermines defrost even if the coil and refrigerant circuit are fine.
Likely causes
- Outdoor defrost thermistor inoperable (open or shorted)
- Defrost thermistor not properly connected
- Defrost thermistor out of range
How to fix it — step by step
- Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E27) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
- Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
- Locate the part: the outdoor defrost thermistor (defrost sensor) is clipped to the outdoor coil/feeder tube on the AVZC20 outdoor unit, with its lead running to the outdoor control board in the control compartment, where E27 is read on the board's LED display.
- Test: with power off, follow the lead from the coil to the board and reseat the connector, then unplug the thermistor and measure its resistance against the coil's actual temperature - OL or near-zero ohms, or a value far from what that temperature should give, proves the sensor is out of range and condemns it. → Shop the thermistor at Amazon
- End at the fix: repair the connection or replace the Defrost sensor as the test condemns, restore power, run a heating call (a forced defrost from the thermostat's ComfortNet user menu confirms defrost now starts and ends), and confirm E27 does not return; a good sensor that still sets E27 points to the Control board. → Shop the defrost sensor at Amazon → Shop the control board at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the Defrost sensor.
Shop the Defrost sensor at Amazon
Also tied to this fault: Thermistor - Shop at Amazon; Control board - Shop at Amazon
Parts that commonly fix the E27 code
- Defrost sensor$25–$80Shop at Amazon
- Thermistor$25–$80Shop at Amazon
- Control boardShop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.