Amana Heat pump Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 20 codes covered.
Finding your model number: it is on the outdoor unit's rating plate.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
AVZC20 (inverter, communicating)
Faults show as numbers on the outdoor unit's PCB LED display and are transmitted to the ComfortNet thermostat as ClimateTalk E-codes.
| Code | What it means | Check first | |
|---|---|---|---|
| E12 | Shown as PCB LED display 12 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | High electrical noise on the control circuit | › |
| E13 | Shown as PCB LED display 13 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Blocked/restricted condenser coil | › |
| E15 | Shown as PCB LED display 15 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Low refrigerant charge / refrigerant leak | › |
| E17 | Shown as PCB LED display 17 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Compressor wire lost phase / broken compressor lead | › |
| E18 | Shown as PCB LED display 18 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Faulty outdoor control board (internal failure) | › |
| E19 | Shown as PCB LED display 19 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Outdoor fan motor not connected properly | › |
| E20 | Shown as PCB LED display 20 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Outdoor EEV coil not connected at the control board | › |
| E21 | Shown as PCB LED display 21 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Thermistors inoperable or improperly connected | › |
| E22 | Shown as PCB LED display 22 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Low refrigerant charge | › |
| E23 | Shown as PCB LED display 23 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Discharge thermistor inoperable | › |
| E24 | Shown as PCB LED display 24 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Inoperable / failed high pressure switch (open) | › |
| E25 | Shown as PCB LED display 25 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Outdoor air thermistor open | › |
| E26 | Shown as PCB LED display 26 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Low pressure sensor inoperable | › |
| E27 | Shown as PCB LED display 27 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Outdoor defrost thermistor inoperable (open or shorted) | › |
| E28 | Shown as PCB LED display 28 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Outdoor coil thermistor inoperable (open or shorted) | › |
| E29 | Shown as PCB LED display 29 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Liquid line thermistor inoperable (open or shorted) | › |
| E30 | Shown as PCB LED display 30 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Wiring to the outdoor control board disconnected | › |
| E31 | Shown as PCB LED display 31 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Improper ground / loose ground screws or lugs | › |
| E32 | Shown as PCB LED display 32 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Ambient air conditions too high | › |
| E34 | Shown as PCB LED display 34 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk… | Current spike in the power supply | › |
Common questions
What does E18 mean on an Amana AVZC20 heat pump?
An outdoor control failure - the AVZC20 outdoor chart lists display 18 / ClimateTalk E18 as 'OD CTRL FAIL2'. The manual's thermostat message is direct: the outdoor control itself has failed.
Where does an Amana AVZC20 show its fault codes?
Two places: as a number on the outdoor unit's PCB LED display, and as an E-code at the ComfortNet communicating thermostat. The outdoor display number and the thermostat E-code are the same fault.
Once you know the part you need, browse Amana Heat pump replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.