Amana Heat pump AVZC20 series E12 Error Code

What the E12 code means

Shown as PCB LED display 12 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E12, this is the AVZC20 outdoor chart's 'OD CTRL FAIL1.' The thermostat message in the manual is that it indicates a general memory error, and the probable causes listed are high electrical noise or a faulty control board, with the corrective action to replace the control board if necessary. It is an outdoor-control failure, not a refrigerant fault: the inverter outdoor control's own memory/logic is reporting itself unreliable, so the board is the suspect part.

Likely causes

  1. High electrical noise on the control circuit
  2. Faulty outdoor control board (general memory error)

How to fix it — step by step

  1. Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E12) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
  2. Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
  3. Locate the part: the outdoor control board (PCB) is inside the AVZC20 outdoor unit's control compartment, behind its access panel; the E12 code is read on that board's LED display and at the ComfortNet thermostat indoors.
  4. Test: with power off, inspect the board's power and ground connections for looseness or corrosion and confirm the unit has a solid ground - a board with clean, tight power and ground that repeatedly sets E12 has failed its own memory check, which no external sensor test can clear.
  5. End at the fix: correct any wiring/ground fault found, restore power and run the system; if E12 returns, the pinpointed cause is the outdoor Control board - replace it. Inverter control replacement and setup is technician work. → Shop the control board at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E12 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Amana Heat pump AVZC20 series error codes

See all Amana AVZC20 series codes & guides →