Amana Heat pump AVZC20 series E29 Error Code
What the E29 code means
Shown as PCB LED display 29 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E29, this is the AVZC20 outdoor chart's 'LIQ TEMP FAIL.' The thermostat message says the control has detected that the liquid temperature sensor is out of range, the probable cause listed is a liquid thermistor inoperable or not properly connected, and the corrective action is to check the connection to the liquid thermistor and repair or replace if needed. The liquid-line temperature is one of the inputs the inverter control uses to manage the electronic expansion valve and superheat, so a bad reading degrades capacity and can trigger follow-on EEV faults.
Likely causes
- Liquid line thermistor inoperable (open or shorted)
- Liquid thermistor not properly connected
- Liquid thermistor out of range
How to fix it — step by step
- Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E29) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
- Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
- Locate the part: the liquid temperature thermistor is clipped to the liquid refrigerant line inside the AVZC20 outdoor unit, with its lead plugged into the outdoor control board in the control compartment, where E29 is read on the board's LED display.
- Test: with power off, reseat the thermistor's connector, then unplug it and measure its resistance against the liquid line's actual temperature - OL proves an open sensor or lead, near-zero ohms a short, and a reading that does not match the line temperature proves an out-of-range sensor; each result condemns the sensor, not the valve it informs. → Shop the thermistor at Amazon
- End at the fix: repair the connection or replace the Thermistor as the test condemns, restore power and run the system to confirm E29 clears and no EEV fault follows it; a verified-good sensor that still sets E29 pinpoints the Control board. → Shop the control board at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the Thermistor.
Also tied to this fault: Control board - Shop at Amazon
Parts that commonly fix the E29 code
- Thermistor$25–$80Shop at Amazon
- Control boardShop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.