Amana Heat pump AVZC20 series E23 Error Code

What the E23 code means

Shown as PCB LED display 23 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E23, this is the AVZC20 outdoor chart's 'DISCH TEMP FAIL' - a discharge temperature sensing failure, distinct from E22's genuinely high temperature. The chart's messages are that the discharge thermistor is not put on the correct position, and that the control has detected the discharge temperature sensor is out of range. Probable cause listed is a discharge thermistor inoperable or improperly connected, and the corrective action is to check the discharge thermistor's resistance and connections and repair or replace as needed.

Likely causes

  1. Discharge thermistor inoperable
  2. Discharge thermistor improperly connected
  3. Discharge thermistor not in its correct position on the line

How to fix it — step by step

  1. Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E23) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
  2. Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
  3. Locate the part: the discharge thermistor is clipped to the compressor discharge line near the compressor in the base of the AVZC20 outdoor unit, with its lead plugged into the outdoor control board in the control compartment, where E23 is read on the board's LED display.
  4. Test: with power off, inspect the thermistor's position on the discharge line first - a sensor that has slipped off or sits on the wrong spot matches the chart's first message exactly. Then unplug it and measure resistance: OL proves an open sensor/lead and near-zero a short, either of which is 'out of range' and condemns the sensor; a correct reading with correct position points to the board input.
  5. End at the fix: reposition the thermistor correctly or replace the Thermistor if it tests open, shorted or out of range, restore power and run the unit to confirm E23 clears; if a known-good, correctly placed sensor still sets E23, replace the Control board. → Shop the thermistor at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E23 code

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.