Amana Heat pump AVZC20 series E25 Error Code
What the E25 code means
Shown as PCB LED display 25 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E25, this is the AVZC20 outdoor chart's 'AIR SENSOR FLT.' The thermostat message says the outdoor air temperature sensor is open or shorted, the probable cause listed is a faulty outdoor thermistor sensor or a disconnect, and the corrective action is to inspect and test the sensor and replace it if needed. This ambient sensor feeds the inverter control's capacity, defrost and low-ambient decisions, so an open or shorted reading corrupts operation well beyond a wrong temperature display.
Likely causes
- Outdoor air thermistor open
- Outdoor air thermistor shorted
- Sensor disconnected from the outdoor control board
How to fix it — step by step
- Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E25) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
- Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
- Locate the part: the outdoor air temperature thermistor is mounted at the AVZC20 outdoor unit where it samples ambient air, with its two-wire lead plugged into the outdoor control board in the control compartment, where E25 is read on the board's LED display.
- Test: with power off, unplug the sensor and measure its resistance, comparing it with the actual outdoor temperature - OL proves an open sensor or lead and near-zero ohms proves a short, both of which are exactly what the code reports; a plausible resistance that tracks temperature means the sensor is good and the connection or board input is at fault.
- End at the fix: replace the Thermistor if it tests open or shorted, or reseat/repair its connection, restore power and confirm E25 clears and the thermostat's outdoor temperature reading is sane; if a good sensor still sets E25, replace the Control board. → Shop the thermistor at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the Thermistor.
Also tied to this fault: Control board - Shop at Amazon
Parts that commonly fix the E25 code
- Thermistor$25–$80Shop at Amazon
- Control boardShop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.