Amana Heat pump AVZC20 series E26 Error Code

What the E26 code means

Shown as PCB LED display 26 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E26, this is the AVZC20 outdoor chart's 'PRESSURE SENSOR' fault. The thermostat message says the control determines that the pressure sensor is not reacting properly, the probable cause listed is a low pressure sensor inoperable or not properly connected, and the corrective action is to check the connection to the low pressure sensor and repair or replace if needed. Because the inverter control runs the compressor and EEV off this sensor's feedback, a sensor that lies - rather than one that is simply open - produces exactly this 'not reacting' verdict.

Likely causes

  1. Low pressure sensor inoperable
  2. Low pressure sensor not properly connected
  3. Pressure sensor signal not reacting to system pressure changes

How to fix it — step by step

  1. Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E26) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
  2. Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
  3. Locate the part: the low pressure sensor is fitted to the low-side refrigerant line inside the AVZC20 outdoor unit, with its harness plugged into the outdoor control board in the control compartment, where E26 is read on the board's LED display.
  4. Test: with power off, reseat and inspect the sensor's connector and harness for damage - a loose connection is the chart's named cause. Confirming the sensor 'reacts properly' requires comparing its reported pressure against a gauge manifold reading while the system runs, which is sealed-system gauge work: a sensor whose reading stays frozen while gauge pressure moves is proven faulty.
  5. End at the pinpoint: repair the connection if that was the fault; a sensor proven unresponsive against gauges is replaced, and because that comparison and any line opening are sealed-system work, this code's confirmation and fix are EPA-certified technician work.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E26 code

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.