Amana Heat pump AVZC20 series E15 Error Code
What the E15 code means
Shown as PCB LED display 15 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E15, this is the AVZC20 outdoor chart's 'LOW PRESSURE C' - the C marking denotes a critical low-pressure fault. The thermostat message says the equipment is experiencing frequent low pressure faults. Probable causes listed are a stop valve not completely open, a restriction in the refrigerant lines, low refrigerant charge, a refrigerant leak, a low pressure sensor inoperable or not properly connected, the indoor fan motor not functioning correctly, a faulty TXV, or a faulty control board.
Likely causes
- Low refrigerant charge / refrigerant leak
- Restriction in the refrigerant lines
- Stop valve not completely open
- Low pressure sensor inoperable or disconnected
- Indoor fan motor not functioning correctly
How to fix it — step by step
- Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E15) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
- Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
- Locate the part: the low pressure sensor and refrigerant lines are inside the AVZC20 outdoor unit (access panels off), the stop valves are at the unit's line connections, the indoor fan is at the air handler, and the code is read on the outdoor control board's LED display.
- Test: first prove the simple causes - confirm the stop valves are fully open and the indoor blower runs with a clean filter, since low indoor airflow drives suction pressure down. Then check the low pressure sensor's connection at the outdoor board; sealed-system proof (suction pressure and charge) is gauge work that distinguishes low charge/leak from a line restriction, and is certified-technician only.
- End at the pinpoint: reseat/repair the pressure sensor connection or correct the airflow/valve fault found; if those are proven good, the pinpoint is low charge from a leak or a restricted line, and leak repair, restriction removal and recharge are EPA-certified work only.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Thermistor.
Also tied to this fault: Air filter - Shop at Amazon
Parts that commonly fix the E15 code
- Thermistor$25–$80Shop at Amazon
- Air filter$5–$30Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.