Amana Heat pump AVZC20 series E20 Error Code

What the E20 code means

Shown as PCB LED display 20 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E20, this is the AVZC20 outdoor chart's 'EEV OPEN CKT.' The thermostat message states the cause plainly: the EEV coil is not connected. The chart's probable causes are that the outdoor EEV coil is not connected or is faulty, and the corrective action is to check the outdoor EEV coil connection and repair or replace as needed. The electronic expansion valve meters refrigerant into the outdoor coil in heating, so an open coil circuit leaves the valve unable to move and the heat pump unable to heat correctly.

Likely causes

  1. Outdoor EEV coil not connected at the control board
  2. Faulty / open outdoor EEV coil
  3. Damaged EEV coil harness

How to fix it — step by step

  1. Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E20) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
  2. Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
  3. Locate the part: the outdoor electronic expansion valve (EEV) and its coil are on the refrigerant line inside the AVZC20 outdoor unit, with the coil's harness plugged into the outdoor control board in the control compartment; the code is read on that board's LED display.
  4. Test: with power off, reseat the EEV coil connector at the board and then unplug the coil and measure its resistance - an open circuit (OL) proves the coil or its harness is open, which is exactly the fault the code names; a coil with normal resistance and a seated connector points to the board's EEV drive output.
  5. End at the fix: repair the connection or replace the faulty EEV coil/harness as the resistance test condemns, restore power and run a heating call to confirm the valve steps and E20 clears; if coil and harness prove good, replace the Control board.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E20 code

  • Control boardShop at Amazon
  • Tools for this job, if you need them$15–$65

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Amana Heat pump AVZC20 series error codes

See all Amana AVZC20 series codes & guides →