Amana Heat pump AVZC20 series E24 Error Code
What the E24 code means
Shown as PCB LED display 24 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E24, this is the AVZC20 outdoor chart's 'HPS OPEN': the thermostat message is simply that the high pressure switch is open. The probable cause listed is an inoperable high pressure switch (HPS), and the corrective action is to check the resistance on the HPS to verify operation and replace it if needed. An open high-pressure switch stops the compressor to protect the system - but the chart's point is that the switch itself may be the failure, opening when pressure is not actually high.
Likely causes
- Inoperable / failed high pressure switch (open)
- High pressure switch wiring or connection fault
How to fix it — step by step
- Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E24) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
- Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
- Locate the part: the high pressure switch is threaded onto the high-side (discharge/liquid) refrigerant line inside the AVZC20 outdoor unit, wired back to the outdoor control board in the control compartment, where E24 is read on the board's LED display.
- Test: with the system at rest and pressures equalised, check the switch's resistance/continuity - a healthy HPS is closed at rest pressure, so an open reading on a resting, charged system proves the switch (or its leads) is faulty rather than a genuine over-pressure event. Verifying actual operating pressure, if the switch tests good, is gauge work.
- End at the pinpoint: replace the high pressure switch if it tests open at rest, or repair its wiring; if the switch proves good, the pinpoint is genuine high pressure and its sealed-system diagnosis is EPA-certified technician work only.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the fault is internal - there is no documented owner fix beyond the steps above. If you're not comfortable taking it apart yourself, a repair shop is the next step.
Parts that commonly fix the E24 code
No specific replacement part is documented for this fault. If the checks above do not clear it, your heat pump likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.