Amana Heat pump AVZC20 series E13 Error Code
What the E13 code means
Shown as PCB LED display 13 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E13, this is the AVZC20 outdoor chart's 'HI PRESSURE C' - the C marking denotes a critical high-pressure fault. The thermostat message says the equipment is experiencing frequent high pressure faults. Probable causes listed are a blocked or restricted condenser coil and/or lines, a stop valve not completely open, overcharge, the outdoor fan not running, an inoperable high pressure switch, a faulty TXV, or a faulty control board. Repeated high-pressure events risk compressor damage, which is why this one is classed critical.
Likely causes
- Blocked/restricted condenser coil
- Outdoor fan not running
- Refrigerant overcharge
- Stop valve not completely open
- Inoperable high pressure switch
How to fix it — step by step
- Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E13) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
- Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
- Locate the part: the outdoor coil wraps the inside of the AVZC20 cabinet, the outdoor fan motor is under the top grille, the stop (service) valves are at the unit's refrigerant connections, and the code is read on the outdoor control board's LED display in the control compartment.
- Test: inspect and clean-check the coil and confirm the outdoor fan actually runs on a call - a stopped fan or matted coil is direct evidence. Anything deeper (operating pressures, charge weight, high pressure switch operation) is gauge work on the sealed system and proves charge/restriction causes, but only for a certified technician.
- End at the pinpoint: clean the coil or repair/replace the Outdoor fan motor as the checks condemn and confirm the stop valves are fully open; if airflow is proven good, the pinpoint is a sealed-system cause (overcharge, restriction, switch or TXV) and the fix is EPA-certified technician work only. → Shop the outdoor fan motor at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Outdoor fan motor.
Shop the Outdoor fan motor at Amazon
Also tied to this fault: Control board - Shop at Amazon
Parts that commonly fix the E13 code
- Outdoor fan motorShop at Amazon
- Control boardShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.