Amana Heat pump AVZC20 series E34 Error Code
What the E34 code means
Shown as PCB LED display 34 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E34, this is the AVZC20 outdoor chart's 'CURRENT SPIKE.' The thermostat message says the board detected a high current condition, indicating the potential for a short circuit. Probable causes listed are a current spike in the supply, a stop valve not completely open, the compressor wire having lost a phase, a faulty control board, or a faulty compressor, with corrective actions to check the supply for in-rush current during start-up or steady state, check the stop valve is full open, check the wire between control board and compressor, and check the compressor.
Likely causes
- Current spike in the power supply
- Compressor wire lost phase
- Faulty compressor
- Stop valve not completely open
- Faulty outdoor control board
How to fix it — step by step
- Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E34) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
- Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
- Locate the part: the compressor and its leads from the inverter outdoor control board are inside the AVZC20 outdoor unit (base and control compartment, access panels off), the stop valves are at the line connections, and the code is read on the outdoor board's LED display.
- Test: with power off, continuity-check each compressor lead from board to compressor (an open lead is the lost-phase cause) and ohm the compressor windings for balance and shorts to ground. Checking the supply for in-rush spikes during start-up requires a clamp meter on a live start - qualified-technician measurement only; a compressor and wiring set that tests clean with a proven supply points to the control board.
- End at the pinpoint: repair the compressor lead or open the stop valve fully as found; a compressor that tests shorted/unbalanced is the pinpoint and its replacement is sealed-system EPA-certified work, as is a Control board replacement if the drive is proven faulty.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Control board.
Parts that commonly fix the E34 code
- Control boardShop at Amazon
- Tools for this job, if you need them$15–$65
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.