Amana Heat pump AVZC20 series E19 Error Code
What the E19 code means
Shown as PCB LED display 19 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E19, this is the AVZC20 outdoor chart's 'PCB OR FAN FAIL.' The thermostat message says the equipment is experiencing frequent outdoor control board and/or motor faults. Probable causes listed are the outdoor fan motor not connected properly, a faulty control board, noise, or an obstruction in fan rotation, with corrective actions to check the wiring from the outdoor fan motor to the control board, check and clean the grille or any debris, check the outdoor fan motor and wiring, and replace the control board if necessary.
Likely causes
- Outdoor fan motor not connected properly
- Obstruction in fan rotation / debris at the grille
- Faulty outdoor control board
- Electrical noise
How to fix it — step by step
- Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E19) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
- Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
- Locate the part: the outdoor fan motor is under the AVZC20's top grille driving the fan blade, its harness runs to the outdoor control board in the control compartment, and the code is read on that board's LED display behind the access panel.
- Test: with power off, spin the fan blade by hand - resistance or a catch proves an obstruction or bearing problem, and inspect the grille for debris. Check the motor's connector at the control board is fully seated; a free-spinning fan with a seated connector that still will not run on a call separates into motor versus board drive, proven by the board's output to the motor.
- End at the fix: clear the obstruction/debris or repair the motor wiring connection, or replace the Outdoor fan motor or Control board as the tests condemn, then run the unit and confirm E19 stays clear. → Shop the outdoor fan motor at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Outdoor fan motor.
Shop the Outdoor fan motor at Amazon
Also tied to this fault: Control board - Shop at Amazon
Parts that commonly fix the E19 code
- Outdoor fan motorShop at Amazon
- Control boardShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Amana manual is on Amana's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.