Amana Heat pump AVZC20 series E21 Error Code
What the E21 code means
Shown as PCB LED display 21 on the outdoor unit and transmitted to the ComfortNet thermostat as ClimateTalk fault E21, this is the AVZC20 outdoor chart's 'EEV CTRL FAIL.' The thermostat message says the equipment is experiencing frequent low discharge superheat faults. Probable causes listed are thermistors inoperable or improperly connected, a faulty TXV, a faulty outdoor EEV coil, a faulty outdoor EEV, overcharge, a faulty pressure sensor, or a faulty control board. Because the control judges the valve by the temperatures and pressures it sees, bad sensor inputs can make a good valve look guilty - the chart's own list puts thermistors first.
Likely causes
- Thermistors inoperable or improperly connected
- Faulty outdoor EEV or EEV coil
- Refrigerant overcharge
- Faulty pressure sensor
- Faulty control board
How to fix it — step by step
- Record the code before cycling power: note the number on the outdoor unit's PCB LED display and the transmitted ClimateTalk fault code (for example E21) shown at the ComfortNet thermostat, and write down whether the unit was heating, cooling or in defrost when it appeared.
- Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC at the outdoor control with a meter before touching wiring, and treat capacitors and the inverter board as charged - wait and re-verify 0 V before handling them.
- Locate the part: the outdoor EEV and its coil are on the refrigerant line inside the AVZC20 outdoor unit, the thermistors are clipped to the coil/discharge/liquid lines with leads to the outdoor control board in the control compartment, where the code is read on the board's LED display.
- Test: with power off, check each thermistor's connection and resistance against the ambient/line temperature - an open, shorted or wildly off thermistor proves a bad input and must be fixed before the valve is condemned. EEV coil resistance and refrigerant charge/superheat measurement follow; superheat and charge work is gauge work on the sealed system. → Shop the thermistor at Amazon
- End at the pinpoint: replace a Thermistor that tests faulty or repair its connection; if sensors, coil and charge are proven good, the pinpoint is the EEV itself or the Control board, and valve or sealed-system work is EPA-certified technician work only.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Thermistor.
Also tied to this fault: Control board - Shop at Amazon
Parts that commonly fix the E21 code
- Thermistor$25–$80Shop at Amazon
- Control boardShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.