Lennox Heat pump Common Problems

Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 20 problems covered.

Finding your model number: it is on the outdoor unit's rating plate.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

ML14XP1 (defrost control LEDs)

Two LEDs on the CMC1 defrost control - DS2 (green) and DS1 (red) - combine into the fault and lockout patterns.

ProblemWhat it meansCheck first
Green LED (DS2) off, red LED (DS1) onTable 3 of the ML14XP1 instructions lists green off with red on, under Fault and Lockout Codes, as a low…Refrigerant leak or undercharge severe enough to trip the switch repeatedly›
Green LED (DS2) off, red LED (DS1) slow flashOn the ML14XP1 defrost control (CMC1), Table 3 of the Lennox installation instructions lists this DS2/DS1…Low refrigerant charge or a refrigerant leak›
Green LED (DS2) on, red LED (DS1) offTable 3 of the ML14XP1 instructions lists green on with red off as a high pressure switch lockout. The manual…Outdoor fan motor failed or its capacitor weak, so the coil cannot shed heat›
Green LED (DS2) slow flash, red LED (DS1) offOn the ML14XP1 defrost control (CMC1), Table 3 lists green slow flash with red off under Fault and Lockout…Outdoor fan not running or running weakly in cooling›

XP17 (Alert codes)

Communicating-system Alert codes in the 400 series, shown at the control and thermostat.

ProblemWhat it meansCheck first
Alert 400The XP17 installation instructions (506586-01), Table 15, pair iComfort Touch thermostat Alert Code 400 with…Compressor internal overload open from high head pressure›
Alert 402Table 15 of the XP17 instructions pairs Alert Code 402 with 'System pressure trip'. Lennox's text says it…High head pressure from refrigerant overcharge›
Alert 404Alert Code 404 in XP17 Table 15 is 'Locked rotor', a critical alert. Lennox describes the compressor as…Failed or shorted run capacitor›
Alert 405Alert Code 405 in XP17 Table 15 is 'Open circuit', a critical alert: the compressor has an open circuit due…Outdoor disconnect open or breaker/fuse open›
Alert 406Alert Code 406 in XP17 Table 15 is 'Open start circuit', a critical alert: current is not sensed by the start…Failed run capacitor›
Alert 407Alert Code 407 in XP17 Table 15 is 'Open run circuit', a critical alert: current is not sensed by the run…Open run wiring or loose connector at the compressor R terminal›
Alert 408Alert Code 408 in XP17 Table 15 is 'Welded contactor', a critical alert: the compressor always runs. Lennox…Contactor contacts welded or fused shut›
Alert 409Alert Code 409 in XP17 Table 15 is 'Secondary low voltage': the 24VAC secondary is below 18VAC. Lennox lists…Control transformer overloaded by connected accessories or a partial short›
Alert 410In the XP17 fault and lockout table (Table 14 in 506586-01), Alert Code 410 is 'Low pressure fault', a…Restricted airflow over indoor or outdoor coil›
Alert 411Alert Code 411 in the XP17 table is 'Low pressure switch lockout', a critical alert: the low pressure switch…Refrigerant undercharge or leak causing repeated low-pressure trips›
Alert 412Alert Code 412 in the XP17 table is 'High pressure fault', a moderate alert: discharge pressure rose high…Outdoor coil dirty or blocked, or outdoor fan not moving air›
Alert 413Alert Code 413 in the XP17 table is 'High pressure switch lockout', a critical alert: repeated high pressure…Outdoor fan failed or coil fouled so heat cannot be rejected in cooling›
Alert 414Alert Code 414 in the XP17 table is 'Discharge line temperature fault'. Lennox's own explanation is precise…Low refrigerant charge raising discharge superheat›
Alert 415Alert Code 415 in the XP17 table is 'Discharge line temperature lockout', a critical alert: the high…Low refrigerant charge or a leak›
Alert 417Alert Code 417 in the XP17 table is 'Discharge sensor fault'. Lennox explains the detection exactly: the heat…Discharge sensor open, shorted or out of resistance range›
Alert 421Alert Code 421 in the XP17 table is 'W external miswire fault', a critical alert. Lennox's condition text is…Low-voltage wiring error on the W circuit after installation or service›

Common questions

What does Alert 402 mean on a Lennox XP17?
A system pressure trip: Lennox's table says the compressor protector is open or supply power to the compressor is missing, with high pressure among the listed causes.

What does a slow red flash with the green LED off mean on a Lennox ML14XP1?
A low pressure switch fault. On the CMC1 defrost control, DS2 (green) off with DS1 (red) slow-flashing is Table 3's low pressure switch fault pattern.