Lennox Heat pump XP17 Alert 412
What this problem usually means
Alert Code 412 in the XP17 table is 'High pressure fault', a moderate alert: discharge pressure rose high enough to trip the high pressure protection once, but the control has not locked out. It sits in the same pressure-fault group for which Lennox prints the causes (restricted airflow over the indoor or outdoor coil, improper refrigerant charge, improper metering device, incorrect sensor location or connection) and the checks (clear coil and fan blockages, verify fan motor current draws, check charge by approach and subcooling, compare operating pressures with the charging charts, and secure all pressure switch and sensor connections). In cooling, a dirty outdoor coil or dead fan is the usual driver; in heating, indoor airflow is.
Likely causes
- Outdoor coil dirty or blocked, or outdoor fan not moving air
- Indoor airflow restricted in heating, including a clogged filter
- Refrigerant overcharge
- Metering device or sensor connection problem
How to fix it — step by step
- Record Alert 412 and the mode (heating or cooling) before cycling power, because the likely airflow side depends on the mode.
- Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
- Inspect and clean the outdoor coil, confirm the outdoor fan runs, replace a clogged indoor filter, then check pressure switch and sensor connections at the heat pump control (A175) in the control box.
- Have a technician compare operating pressures with the unit charging chart and check charge by approach and subcooling, plus fan current draws as the manual directs; high pressure with clean coils and correct charge points to the metering device or a sensor fault.
- Correct the airflow cause or have charge corrected; Any refrigerant-side repair, charge adjustment or sealed-system work is EPA-certified-technician work only; do not open the refrigerant circuit yourself. Run a full cycle and confirm the fault does not return toward lockout.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Air filter.
Also tied to this fault: Outdoor fan motor - Shop at Amazon
Parts that commonly fix it
- Air filter$5–$30Shop at Amazon
- Outdoor fan motorShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.