Lennox Heat pump XP17 Alert 417
What this problem usually means
Alert Code 417 in the XP17 table is 'Discharge sensor fault'. Lennox explains the detection exactly: the heat pump control (A175) detects an open or shorted sensor, or a sensor out of its temperature range, and it allows the unit to run for 90 seconds before checking sensor resistance; if the resistance is not within range after 90 seconds, the control raises the alarm. That 90-second delay matters for diagnosis: a sensor that only fails hot, or a marginal connection that opens with vibration, can pass a cold static check and still set 417 in the first minutes of a run. Without a believable discharge temperature, the control cannot protect the compressor from overheating.
Likely causes
- Discharge sensor open, shorted or out of resistance range
- Loose or corroded sensor connector at the control
- Sensor wiring chafed or damaged
- Sensor poorly mounted so it reads out of range
How to fix it — step by step
- Record Alert 417 and note how long the unit ran before it appeared; the manual's 90-second check window is a diagnostic clue.
- Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
- Remove the control-box panel, locate the discharge sensor on the compressor discharge line and trace its leads back to the heat pump control (A175), checking the connector seating.
- Measure the sensor's resistance and compare it with the temperature/resistance relationship for the actual line temperature; an open, shorted or wildly off reading condemns the sensor, while a correct reading at the sensor but not at the control condemns the wiring or connector.
- Replace a proven-bad discharge sensor (thermistor) or repair the wiring, then run the unit past the 90-second check and confirm the alert stays clear.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Thermistor.
Parts that commonly fix it
- Thermistor$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.