Lennox Heat pump XP17 Alert 405

What this problem usually means

Alert Code 405 in XP17 Table 15 is 'Open circuit', a critical alert: the compressor has an open circuit due to a power disconnection, an open fuse or similar conditions. Lennox's cause list runs from the outdoor unit power disconnect being open, the unit circuit breaker or fuses being open, and the contactor failing to close (check its wiring, connectors, burned or pitted contacts and pilot voltage at the coil), through a high pressure switch open and requiring manual reset, an open circuit in the compressor supply wiring, an unusually long protector reset time in extreme ambient, to damaged compressor windings, checked by winding resistance. It clears after one normal run cycle or a power reset.

Likely causes

  1. Outdoor disconnect open or breaker/fuse open
  2. Contactor failed to close or its contacts burned open
  3. High pressure switch open
  4. Open compressor supply wiring or connector
  5. Compressor windings damaged or open

How to fix it — step by step

  1. Record Alert 405 before resetting, and check the obvious power path first: disconnect position and breaker state.
  2. Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
  3. Remove the control-box panel to reach the contactor (K1), heat pump control (A175) and compressor leads; inspect for burned, pitted contactor contacts and loose or heat-damaged connectors.
  4. Verify line voltage into the contactor and 24V pilot voltage at its coil on a call, then have a technician check continuity through the high pressure switch and measure compressor winding resistance; voltage in with no voltage out condemns the contactor, while an open winding reading condemns the compressor. → Shop the contactor at Amazon
  5. Replace a proven-bad contactor or repair the open wiring, reset any manual-reset pressure switch per the manual, and confirm one normal run cycle clears the alert.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $10–$35
  • Contactor$10–$35Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Lennox Heat pump XP17 problems

See all Lennox XP17 codes & guides →