Lennox XP17 Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 16 problems covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Problem | What it means | Check first | |
|---|---|---|---|
| Alert 400 | The XP17 installation instructions (506586-01), Table 15, pair iComfort Touch thermostat Alert Code 400 with… | Compressor internal overload open from high head pressure | › |
| Alert 402 | Table 15 of the XP17 instructions pairs Alert Code 402 with 'System pressure trip'. Lennox's text says it… | High head pressure from refrigerant overcharge | › |
| Alert 404 | Alert Code 404 in XP17 Table 15 is 'Locked rotor', a critical alert. Lennox describes the compressor as… | Failed or shorted run capacitor | › |
| Alert 405 | Alert Code 405 in XP17 Table 15 is 'Open circuit', a critical alert: the compressor has an open circuit due… | Outdoor disconnect open or breaker/fuse open | › |
| Alert 406 | Alert Code 406 in XP17 Table 15 is 'Open start circuit', a critical alert: current is not sensed by the start… | Failed run capacitor | › |
| Alert 407 | Alert Code 407 in XP17 Table 15 is 'Open run circuit', a critical alert: current is not sensed by the run… | Open run wiring or loose connector at the compressor R terminal | › |
| Alert 408 | Alert Code 408 in XP17 Table 15 is 'Welded contactor', a critical alert: the compressor always runs. Lennox… | Contactor contacts welded or fused shut | › |
| Alert 409 | Alert Code 409 in XP17 Table 15 is 'Secondary low voltage': the 24VAC secondary is below 18VAC. Lennox lists… | Control transformer overloaded by connected accessories or a partial short | › |
| Alert 410 | In the XP17 fault and lockout table (Table 14 in 506586-01), Alert Code 410 is 'Low pressure fault', a… | Restricted airflow over indoor or outdoor coil | › |
| Alert 411 | Alert Code 411 in the XP17 table is 'Low pressure switch lockout', a critical alert: the low pressure switch… | Refrigerant undercharge or leak causing repeated low-pressure trips | › |
| Alert 412 | Alert Code 412 in the XP17 table is 'High pressure fault', a moderate alert: discharge pressure rose high… | Outdoor coil dirty or blocked, or outdoor fan not moving air | › |
| Alert 413 | Alert Code 413 in the XP17 table is 'High pressure switch lockout', a critical alert: repeated high pressure… | Outdoor fan failed or coil fouled so heat cannot be rejected in cooling | › |
| Alert 414 | Alert Code 414 in the XP17 table is 'Discharge line temperature fault'. Lennox's own explanation is precise… | Low refrigerant charge raising discharge superheat | › |
| Alert 415 | Alert Code 415 in the XP17 table is 'Discharge line temperature lockout', a critical alert: the high… | Low refrigerant charge or a leak | › |
| Alert 417 | Alert Code 417 in the XP17 table is 'Discharge sensor fault'. Lennox explains the detection exactly: the heat… | Discharge sensor open, shorted or out of resistance range | › |
| Alert 421 | Alert Code 421 in the XP17 table is 'W external miswire fault', a critical alert. Lennox's condition text is… | Low-voltage wiring error on the W circuit after installation or service | › |
All Lennox heat pump models & codes →