Lennox Heat pump XP17 Alert 406
What this problem usually means
Alert Code 406 in XP17 Table 15 is 'Open start circuit', a critical alert: current is not sensed by the start transformer. Lennox lists three causes in order: the run capacitor has failed, an open circuit in the compressor start wiring or connections (check the wiring and connectors between the supply and the compressor S terminal), or the compressor start winding is damaged, checked by measuring compressor motor winding resistance. The alert clears when amperage is detected in both the run and start sensors, or after a power reset. Because the start winding and capacitor are what get a single-phase compressor turning, this code points at the start path specifically, not the whole compressor circuit.
Likely causes
- Failed run capacitor
- Open start wiring or loose connector at the compressor S terminal
- Damaged compressor start winding
How to fix it — step by step
- Record Alert 406 before cycling power, and note whether the compressor hums but does not start, which fits an open start path.
- Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
- Remove the control-box panel to reach the run capacitor (C12) and follow the start wiring to the compressor S terminal as the manual directs.
- Test the capacitor against its marked rating, inspect and continuity-check the start wire and its connectors end to end, and have a technician measure winding resistances; a good capacitor and continuous wiring with an open start-winding reading condemns the compressor.
- Replace a proven-bad run capacitor or repair the start wiring, then run one demand and confirm current is sensed in both sensors and the alert clears.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Run capacitor.
Parts that commonly fix it
- Run capacitor$5–$35Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.