Lennox Heat pump ML14XP1 Green LED (DS2) off, red LED (DS1) on

What this problem usually means

Table 3 of the ML14XP1 instructions lists green off with red on, under Fault and Lockout Codes, as a low pressure switch lockout. The manual's lockout section explains the mechanism: if the low pressure switch (S87) opens five times during a single thermostat demand, the defrost control locks out the compressor and it will not restart on its own. This is the control protecting the compressor from running with too little refrigerant pressure, which starves it of cooling and oil return. The board also ignores the low pressure input in very cold weather, below about 15 degrees F on its on-board thermistor, so a lockout in mild weather is a real system fault.

Likely causes

  1. Refrigerant leak or undercharge severe enough to trip the switch repeatedly
  2. Blocked indoor airflow: clogged filter, closed registers or a failed indoor blower
  3. Outdoor coil blocked or iced over in heating
  4. Failed low pressure switch or chafed switch wiring shorting the input

How to fix it — step by step

  1. Write down the LED pattern and count how the unit behaved before lockout; do not keep resetting it, because each reset lets the compressor run again under the same low-pressure condition.
  2. Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
  3. Remove the control-box access panel and inspect the defrost control (CMC1), the S87 low pressure switch leads on the suction line and the defrost thermostat connections for damage, corrosion or loose plugs.
  4. A technician should connect gauges and compare suction pressure with the manual's values (switch opens below about 25 psig, resets near 40 psig), check the air filter and indoor airflow, and check charge by the access-panel charging chart; pressure that never recovers points to a leak or restriction, while healthy pressure with an open switch condemns the switch.
  5. Fix the proven cause first, then reset the lockout once by cycling 24V control power or shorting the TEST pins for two seconds as the manual directs. Any refrigerant-side repair, charge adjustment or sealed-system work is EPA-certified-technician work only; do not open the refrigerant circuit yourself.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $5–$30

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Lennox Heat pump ML14XP1 problems

See all Lennox ML14XP1 codes & guides →