Lennox Heat pump XP17 Alert 407

What this problem usually means

Alert Code 407 in XP17 Table 15 is 'Open run circuit', a critical alert: current is not sensed by the run transformer. Lennox's causes are an open circuit in the compressor wiring or connections (the manual directs checking wiring and connectors between the supply and the compressor R terminal) or a damaged compressor winding, proven by measuring compressor motor winding resistance. It clears when amperage is detected in the run and start sensors, or after a power reset. Unlike the start-circuit alert, this one says the main run path is open, so the compressor cannot draw running current at all even though a call is present.

Likely causes

  1. Open run wiring or loose connector at the compressor R terminal
  2. Damaged compressor run winding
  3. Contactor contacts open on the run path

How to fix it — step by step

  1. Record Alert 407 before resetting; note whether the contactor pulls in on a call, which separates a control problem from an open run path.
  2. Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
  3. Remove the control-box panel to reach the contactor (K1) and follow the run wiring to the compressor R terminal, per the manual's test direction.
  4. Continuity-check the run wire and connectors, confirm voltage passes through the closed contactor, and have a technician measure compressor winding resistance; an open run-winding reading with good wiring and voltage condemns the compressor.
  5. Repair the proven open (wiring, connector or contactor) and retest once; an open winding means compressor replacement by an EPA-certified technician.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $10–$35
  • Contactor$10–$35Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.