Lennox Heat pump ML14XP1 Green LED (DS2) on, red LED (DS1) off

What this problem usually means

Table 3 of the ML14XP1 instructions lists green on with red off as a high pressure switch lockout. The manual states the defrost control will lock out the compressor if the high pressure switch (S4) opens five times during a single thermostat demand. The switch itself opens above 590 plus or minus 15 psig on the liquid line and resets at 418 plus or minus 15 psig, so five trips in one call means discharge pressure kept climbing to the safety limit again and again. Until the cause is fixed and the lockout is deliberately reset, the compressor stays off, which protects it from destructive head pressure.

Likely causes

  1. Outdoor fan motor failed or its capacitor weak, so the coil cannot shed heat
  2. Outdoor coil heavily fouled, blocked or with recirculating discharge air
  3. Refrigerant overcharge raising head pressure
  4. Failed high pressure switch or damaged switch wiring

How to fix it — step by step

  1. Record the LED pattern before doing anything; repeated manual resets without a repair will keep tripping the switch and stress the compressor.
  2. Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
  3. Remove the control-box access panel to reach the defrost control (CMC1), the contactor and the fan capacitor area; check the outdoor fan spins freely and the coil is clean and unobstructed.
  4. Have a technician measure head pressure against the manual's 590 psig trip and 418 psig reset values, test the run capacitor against its rating (a weak capacitor slows the fan and raises pressure), and check fan motor current; high pressure with a healthy fan and clean coil points to overcharge or restriction, while normal pressure with an open switch condemns the switch. → Shop the run capacitor at Amazon
  5. Replace a proven-bad capacitor, fan motor or pressure switch, or have charge corrected; Any refrigerant-side repair, charge adjustment or sealed-system work is EPA-certified-technician work only; do not open the refrigerant circuit yourself. Then reset once by cycling 24V control power or shorting the TEST pins for two seconds, per the manual.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $5–$35

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.